Dimensions without packaging (H x W x D) [mm(in.)] |
Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 320.0 mm x 210.0 mm (1.72 in. x 12.6 in. x 8.27 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 320.0 mm x 217.0 mm (1.72 in. x 12.6 in. x 8.54 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] |
90.0 mm x 465.0 mm x 380.0 mm (3.54 in. x 18.31 in. x 14.96 in.) |
Chassis height [U] |
1 |
Installation type |
Rack mounting,Desk mounting,Wall mounting |
Chassis material |
Metal |
Weight without packaging [kg(lb)] |
2.23 kg (4.92 lb) |
Weight with packaging [kg(lb)] |
3.05 kg (6.72 lb) |
Typical power consumption [W] |
19.99 W |
Maximum power consumption [W] |
•Without PoE: 25.09 W •Full PoE load: 166.65 W (PoE: 125 W) |
Static power consumption [W] |
17.19 W |
Number of fans modules |
1 |
Maximum number of FE ports |
8 |
Uplink ports |
4 x GE SFP ports |
Downlink ports |
8 x 10/100/1000BASE-T ports (380 W, PoE+) |
Long-term operating temperature [°C(°F)] |
-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] |
When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). Devices cannot start when the temperature is lower than 0°C (32°F). The operating temperature ranges from –5°C (23°F) to +45°C (113°F) when optical modules with transmission distances greater than or equal to 60 km are used. |
Storage temperature [°C(°F)] |
–40°C to +70°C (–40°F to +158°F) |
Long-term operating relative humidity [RH] |
5% RH to 95% RH (non-condensing) |
Long-term operating altitude [m(ft.)] |
0–5000 m (0–16404 ft.) |
Storage altitude [m(ft.)] |
0-5000 m (0-16404 ft.) |
Power supply mode |
AC built-in |
Rated input voltage [V] |
– AC input: 100 V AC to 240 V AC, 50/60 Hz – High-voltage DC input: 240 V DC |
Input voltage range [V] |
– AC input: 90 V AC to 290 V AC; 45 Hz to 65 Hz – High-voltage DC input: 190 V DC to 290 V DC |
Maximum input current [A] |
3 A |
Console port |
RJ45 |
Dying gasp |
Supported |
Service port surge protection [kV] |
Common mode: ±7 kV |
Power supply surge protection [kV] |
Differential mode: ±6 kV; common mode: ±6 kV |
Types of fans |
Built-in |
Heat dissipation mode |
Air cooling for heat dissipation, intelligent fan speed adjustment |
Airflow direction |
Air intake from left and air exhaust from right |
PoE |
Supported |